Top Electrical Issues Found at Home Inspections

Date Published: January 27, 2022

During the course of our 16+ years performing home inspections, with a team of home inspectors in Colorado, we have seen a wide range of electrical issues.  And while we have written a lot of articles on specific issues, we wanted to compile the top electrical issues found at home inspections into one place.

GFCI Outlets Missing or Defective:

This is probably the top electrical issue we find at home inspections.  Because the requirements to have GFCI outlets present has evolved in the building code over the years, and has been adopted at different times by each municipality in the state, we end up seeing quite a variety of what is present, particularly in older homes.  Today’s building codes require GFCI outlets to be installed in all wet locations.

This includes in kitchens, bathrooms, garages, basement areas, and on exterior outlets.  In some older homes, we may only see GFCI outlets present in bathrooms only and not in the kitchen.  Or we may see a single GFCI outlet, for example, in the basement or garage that is then wired to other bathroom or kitchen outlets.  This represents the evolution of the code and the changes made to requirements for GFCIs over the years.

We occasionally will see outlets in the panel that are Ground-Fault outlets that trip within the panel and remove all power to the circuit when a ground fault condition occurs.

Most home inspectors will also test GFCI outlets.  Testing can be done via one of two methods.  The first is to press the reset button on the outlet to ensure that it responds and trips.  The second method is to use a hand-held test device.

These units plug into the outlet and have a test button on them that simulates a ground fault condition.  The outlet should then trip and reset.  On occasion the outlet will not trip or will not reset once tripped, indicating an aged or defective GFCI outlet.  We have written a good summary explaining how GFCI outlets work that goes into more detail.

Ungrounded Outlets:

On many older homes from the 1950s and older, we often come across ungrounded outlets.  Many are still older 2-prong outlets that clearly are not grounded.  But at times the outlets themselves have been updated and are 3-prong style outlets, but are not grounded.

Home inspectors will use a hand-held test device that plugs into the outlet to check for grounding and polarity.  If we come across ungrounded outlets, we note this for reference and recommend that you consider upgrading the outlets for safety protection.  There are a couple ways to do upgrades.  We have a great summary about dealing with ungrounded outlets that is really helpful.

Reverse Polarity Outlets:

This is another safety related concern to be aware of.  If an electrical outlet is wired in reverse, this represents a possible safety hazard to both the person plugging in a device and to the device itself.  We see this frequently on new construction homes where outlets accidentally get mis-wired. The repair of this concern is straightforward for a qualified electrician and involves re-wiring the outlet properly.  This defect was highlighted in an article we wrote about common new construction home defects.

Electrical Panel Age Concerns:

While most of the older home electrical panels have been upgraded or replaced by now, we occasionally run across an older, outdated panel.  Just like most all things in life, electrical panels have evolved and improved over time.  Experience has shown us that some older panels have known concerns that have developed and need to be addressed.  Some are related to the manufacturer of the panel with specific known concerns.

Other issues simply relate to the age, size and performance of the panel.  And example is the Federal Pacific electric panel which was installed in the 1960s and 1970s.  These panels have known concerns with the breakers, outlined in our article about Federal Pacific panels.  Most commonly seen are older, smaller panels that just do not have the capacity to handle the amount of electrical needs of homes today.

Smaller, older panels may have worked well when the home was built, but if the addition of air conditioning, car charging stations, larger capacity appliances, etc. are needed, these panels may be full or simply cannot accommodate the heavier demands.  Upgrading the panel and possibly the incoming electrical service may need to be considered.

Smoke Detector or Carbon Monoxide Detector Concerns:

This is another issue that has evolved over time in the building codes and is one of the top electrical issues found at home inspections.  We see quite a variety of installed configurations with both smoke and CO detectors.  For today’s building code, it is required that there be smoke detectors present in every bedroom and in the common area of each floor of the home, and that all units be hard-wired to an electrical connection with a battery backup.

And in Colorado, there are requirements for CO detectors to be present within 15 ft of the entry to all bedrooms.  But on older homes the units present are usually battery operated only and not hard wired.  And since it is impractical to add wiring to smoke detectors after the fact, we usually are looking to ensure there are at least units within each bedroom for safety.

CO detectors can either be hard-wired, plugged into an outlet or battery operated.  Another concern is the age of the units.  The standard recommendation is that units older than 10 years should be replaced due to aging internal sensors.  Home inspectors will check for all of these items – location, quantity of units, age, and performance.

Home inspectors generally follow a prescribed set of standards when checking electrical concerns in a home.  At Scott Home Inspection, our inspectors follow the ASHI Standards of Practice and the electrical inspection requirements.  The safety of the occupants of a home is one of the top concerns of a home inspector.  Addressing electrical concerns discovered during a home inspection can be done by any licensed electrician.  For more information on the inspection services provided by Scott Home Inspection, visit our Inspection Services page.

Colorado’s Top Rated Inspection Company:

Scott Home Inspection is Colorado’s highest rated inspection company offering home inspections, energy services, and Boulder Rental License Inspections. Click your service to learn more.

Home Inspection Services
Energy Services
Rental Inspections

About the Author: George Scott

George founded Scott Home Inspection in 2006, and has grown the business into a multi-inspector firm serving the Colorado Front Range, from Fort Collins down to Colorado Springs. As an ASHI Certified Home Inspector and Certified Energy Rater, George is an excellent resource to help with inspection and energy-related requirements.

Recent Posts

904, 2024

Home Inspections in Westminster CO

About Westminster Westminster, Colorado is a vibrant suburb that straddles both Adams and Jefferson County, located just several miles north of Denver. Like many other [...]

1403, 2024

Kitec Plumbing: Why Is It Problematic?

Plumbing material is one of the most important components of a residence. Even though most of it is hidden underneath floors, and behind walls and ceilings, it [...]

Ready For A Great Inspection Experience?

Experience quality with the top rated Colorado based company for home inspections, energy services, and rental inspections.

SCHEDULE NOW
OUR SERVICES

Discussion

Visit Our Ask Your Inspector page to see all our posts, find great Colorado contractors, and ask us questions about your home. 

Ask Your Inspector